<html><head><title>SURVEY FORM 25: MERCANTILE FACILITIES</title></head><body><table style="border: medium solid ;" width="100%" cellspacing="1" cellpadding="4" border="1">  <tbody>   <tr>     <td width="66%"><font size="2"><strong>SURVEY FORM 25: MERCANTILE FACILITIES</strong></font></td>    <td width="34%">       <div align="right"><font size="2"><strong>ADA Build it Right, Inc.</strong></font></div>    </td>  </tr>  </tbody> </table><br><div align="left">   <table style="border: thin inset ;" width="100%" cellspacing="1" border="1">    <tbody>     <tr>       <td align="left" valign="top" width="33%"><strong><font size="3">Facility         Name:</font></strong>         <p>&nbsp;</p>      </td>      <td colspan="2" align="center" valign="bottom" width="67%">&nbsp;         <p><small>Check-out Aisles:</small></p>      </td>    </tr>    <tr>       <td rowspan="6" align="left" valign="top" width="33%"><strong>Facility Location:<br>        </strong>         <p><small><small>In addition to the requirements of ADAAG 4.1 through           4.35, mercantile buildings and facilities must comply with ADAAG 7.</small></small></p>      </td>      <td align="center" valign="top" width="34%"><small>Total Check-Out Accessible         Aisles of Each Design:</small></td>      <td align="center" valign="top" width="33%"><small>Minimum Number of Check-Out         Aisles of Each Design:</small></td>    </tr>    <tr>       <td align="center" valign="top" width="34%"><small>1 - 4 </small></td>      <td align="center" valign="top" width="33%"><small>1</small></td>    </tr>    <tr>       <td align="center" valign="top" width="34%"><small>5 - 8 </small></td>      <td align="center" valign="top" width="33%"><small>2 </small></td>    </tr>    <tr>       <td align="center" valign="top" width="34%"><small>9 - 15 </small></td>      <td align="center" valign="top" width="33%"><small>3 </small></td>    </tr>    <tr>       <td align="center" valign="top" width="34%"><small>over 15</small></td>      <td align="center" valign="top" width="33%"><small>3, plus 20% of additional         aisles</small></td>    </tr>    <tr>       <td colspan="2" align="left" valign="top" width="67%"><strong><small>EXCEPTION:         In new construction, where the selling space is under 5,000 square feet,         only one check-out aisle is required to be accessible.</small></strong>         <p><strong><small>EXCEPTION: In alterations, at least one check-out aisle           shall be accessible in facilities under 5,000 square feet of selling           space. In facilities of 5,000 or more square feet of selling space,           at least one of each design of check-out aisle shall be made accessible           when altered until the number of accessible check-out aisles of each           design equals the number required in new construction.</small></strong></p>      </td>    </tr>    </tbody>   </table></div><p><font size="2">&nbsp;</font></p><div align="left">   <table style="border: thin inset ;" width="100%" cellspacing="1" border="1">    <tbody>     <tr>       <td valign="top" width="16%"><small><strong>Section</strong></small></td>      <td valign="top" width="16%"><small><strong>Item</strong></small></td>      <td valign="top" width="32%"><small><strong>Technical Requirements</strong></small></td>      <td valign="top" width="20%"><small><strong>Comments</strong></small></td>      <td valign="top" width="8%"><small><strong>Yes</strong></small></td>      <td valign="top" width="8%"><small><strong>No</strong></small></td>    </tr>    <tr>       <td valign="top" width="16%"><small>7.1 </small></td>      <td valign="top" width="16%"><small>General: </small></td>      <td valign="top" width="32%"><small>Are all areas used for business transactions         with the public accessible as required below?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>7.2(1)</small></td>      <td valign="top" width="16%"><small>Sales/Service Counters- With Cash Registers:         </small></td>      <td valign="top" width="32%"><small>In department stores and miscellaneous         retail stores where counters have cash registers, is there at least one         of each type of counter where a portion of the counter is at least 36         inches long and no more than 36 inches high? </small><br>        <small>OR </small><br>        <small>In alterations, where it is technically infeasible to provide an         accessible counter, is an auxiliary counter meeting the above requirements         provided? </small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="32%"><small>Are the accessible counters dispersed         throughout the building?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>7.2(2) </small></td>      <td valign="top" width="16%"><small>Sales/Service Counters -Without Cash         Registers: </small></td>      <td valign="top" width="32%"><small>At ticketing counters, teller stations,         registration counters and other counters which may not have cash registers,         is there a portion of the main counter at least 36 inches long and no         more than 36 inches high? </small><br>        <small>OR </small><br>        <small>Is there an auxiliary counter at least 36 inches high near the         main counter? </small><br>        <small>OR </small><br>        <small>Is equivalent facilitation provided? (e.g., at a hotel registration         desk, equivalent facilitation might consist of: (1) the provision of a         folding shelf attached to the main counter on which a person with a disability         can write, and (2) use of the space at the side of the counter for handing         materials back and forth.)</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="32%"><small>Do all accessible counters on an accessible         route comply with 4.3? (Use Form 12: Building Corridors and Lobbies)</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>7.3(1) </small></td>      <td valign="top" width="16%"><small>Check-out Aisles - New Construction:         </small></td>      <td valign="top" width="32%"><small>In new construction, does the number         of accessible check-out aisles comply with the table above? </small><br>        <small>OR </small><br>        <small>In new construction where the selling space is under 5,000 square         feet, is at least one check-out aisle accessible?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%"><small>Alterations:</small></td>      <td valign="top" width="32%"><small>In alterations, is at least one check-out         aisle of each design made accessible when altered until the number of         accessible check-out aisles equals the number required in the table above?         OR In alterations of facilities that have under 5,000 square feet of selling         space, is there at least one check-out aisle accessible?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>7.3(2); 4.2.1 </small></td>      <td valign="top" width="16%"><small>Aisle Width: </small></td>      <td valign="top" width="32%"><small>Is the clear aisle width of accessible         check-out aisles at least 36 inches wide for lengths greater than 24 inches         long and at least 32 inches wide for lengths 24 inches or less? </small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="32%"><small>If there is a lip on the edge of the         counter adjoining the aisle, is the top of the lip no more than 40 inches         above the floor?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%"><small>Height: </small></td>      <td valign="top" width="32%"><small>Is the adjoining counter/belt height         no more than 38 inches above the floor?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>7.3(3) </small></td>      <td valign="top" width="16%"><small>Signs: </small></td>      <td valign="top" width="32%"><small>Is there a sign identifying each accessible         check-out aisle which is mounted above the check-out aisle?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="32%"><small>Does the sign include the International         Symbol of Accessibility?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>7.4 </small></td>      <td valign="top" width="16%"><small>Security Bollards: </small></td>      <td valign="top" width="32%"><small>Are security bollards or other such         devices installed so that access and egress for wheelchair users is provided?         </small><br>        <small>OR </small><br>        <small>Is there an alternate accessible entry that is equally convenient         as that provided for the general public?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    </tbody>   </table></div><p align="center"><a href="/SurveySheets/SurveyForm.html"><big>Back to Accessibility   Guidelines Checklist for Building and Facilities</big></a></p><p><font size="2">&nbsp;</font></p></body></html>
