<html><head><title>Survey Form 18: DRESSING AND FITTING ROOMS</title></head><body><table style="border: medium solid ;" width="100%" cellspacing="1" cellpadding="4" border="1">  <tbody>   <tr>     <td width="66%"><strong>SURVEY FORM 18: DRESSING AND FITTING ROOMS</strong></td>    <td width="34%">       <div align="right"><strong>ADA Build it Right, Inc.</strong></div>    </td>  </tr>  </tbody> </table><strong><br></strong> <table style="border: thin inset ;" width="100%" cellspacing="1" border="1">  <tbody>  <tr>     <td align="left" valign="top" width="57%" height="32"><strong><font size="3">Facility       Name:</font></strong></td>    <td align="left" valign="top" width="43%" height="32"><small></small></td>  </tr>  <tr>     <td colspan="2" align="left" valign="top"><strong>Dressing/Fitting Room Location:<br>      </strong></td>  </tr>  </tbody></table><p>&nbsp;</p><div align="left">   <table style="border: thin inset ;" width="100%" cellspacing="1" border="1">    <tbody>    <tr>       <td valign="top" width="16%"><small><strong>Section</strong></small></td>      <td valign="top" width="16%"><small><strong>Item</strong></small></td>      <td valign="top" width="32%"><small><strong>Technical Requirements</strong></small></td>      <td valign="top" width="20%"><small><strong>Comments</strong></small></td>      <td valign="top" width="8%"><small><strong>Yes</strong></small></td>      <td valign="top" width="8%"><small><strong>No</strong></small></td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.1.3(21)<br>        4.35.1</small></td>      <td valign="top" width="16%"><small>Dressing and Fitting Rooms: </small></td>      <td valign="top" width="32%"><small>Where dressing and fitting rooms are         provided for use by the general public, patients, customers or employees,         does 5 percent (but not less than one) of dressing and fitting rooms for         each type of use in each cluster of dressing and fitting rooms comply         with 4.35 (See below)?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.35.1 </small></td>      <td valign="top" width="16%"><small>Accessible Route: </small></td>      <td valign="top" width="32%"><small>Are dressing and fitting rooms that         are required to be accessible located on an accessible route? (Use Form         12: Building Lobbies and Corridors)</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.35.2 </small></td>      <td valign="top" width="16%"><small>Clear Floor Space: </small></td>      <td valign="top" width="32%"><small>In a dressing or fitting room with a         swinging or sliding door, is there clear floor space at least 60 inches         in diameter (or a 60 by 60 inch T-shape) allowing a wheelchair user to         make a 180-degree turn?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%"><small>Door Swing: </small></td>      <td valign="top" width="32%"><small>Is the clear turning space not obstructed         by the door swing?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.35.3<br>        4.13 </small></td>      <td valign="top" width="16%"><small>Doors: </small></td>      <td valign="top" width="32%"><small>Do all doors to accessible dressing         and fitting rooms comply with 4.13? (Use Form 11: Doors and Gates)</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%"><small>Curtained Openings:</small></td>      <td valign="top" width="32%"><small>If the dressing or fitting room is private         and entered through a curtained opening, is the opening at least 32 inches         wide? </small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="32%"><small>Is there adequate clear floor space         in the dressing or fitting room and immediately adjacent to the curtained         opening so that the dressing room is usable by a wheelchair user?</small>        <p>&nbsp;</p>      </td>      <td valign="top" width="20%">&nbsp; </td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.35.4 </small></td>      <td valign="top" width="16%"><small>Bench Affixed to Wall: </small></td>      <td valign="top" width="32%"><small>Does every accessible dressing and fitting         room have a 24 by 48 inch (minimum) bench fixed to the wall along the         longer dimension? (The bench may be a folding type.)</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%"><small>Bench Height: </small></td>      <td valign="top" width="32%"><small>Is the bench mounted 17 to 19 inches         above the finish floor?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="32%"><small>Is there clear floor space at least         30 by 48 inches provided alongside of the bench to allow a person using         a wheelchair to make a parallel transfer onto the bench?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.35.4<br>        4.26.3 </small></td>      <td valign="top" width="16%"><small>Bench Strength: </small></td>      <td valign="top" width="32%"><small>Does the structural strength of the         bench and attachments comply with 4.26.3?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.35.4 </small></td>      <td valign="top" width="16%"><small>Bench in Wet Areas: </small></td>      <td valign="top" width="32%"><small>Where installed in conjunction with         showers, swimming pools or other wet locations, does the surface of the         bench have a slip-resistant surface? </small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="32%"><small>Is the bench in a wet location constructed         so that water does not accumulate on the surface?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.35.5 </small></td>      <td valign="top" width="16%"><small>Mirror: </small></td>      <td valign="top" width="32%"><small>If there is a mirror, is it a full-length         mirror at least 18 inches wide by 54 inches high? </small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="32%"><small>Is the mirror mounted in a position         affording a view to a person on the bench as well as to a person in a         standing position?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    </tbody>  </table></div><p align="center"><a href="SurveyForm.html"><big>Back to Accessibility Guidelines   Checklist for Building and Facilities</big></a></p></body></html>
