<html><head><title>SURVEY FORM 11: DOORS AND GATES</title></head><body><table style="border: medium solid ;" width="100%" cellspacing="1" cellpadding="4" border="1">  <tbody>   <tr>     <td width="100%"><strong>SURVEY FORM 11: DOORS AND GATES</strong></td>    <td width="100%">       <div align="right"><strong>ADA Build it Right, Inc.</strong></div>    </td>  </tr>  <br>  </tbody> <br></table><font size="2"><br></font> <table style="border: thin inset ;" width="100%" cellspacing="1" border="1">  <tbody>  <tr>     <td align="left" valign="top" width="69%" height="36"><strong><font size="3">Facility       Name:</font></strong></td>    <td align="left" valign="top" width="64%" height="36">&nbsp;</td>  </tr>  <tr>     <td colspan="2" align="left" valign="top" width="100%"><strong>Door Location:<br>      </strong></td>  </tr>  </tbody></table><p>&nbsp;</p><div align="left">   <table style="border: thin inset ;" width="100%" cellspacing="1" border="1">    <tbody>    <tr>       <td valign="top" width="16%"><small><strong>Section</strong></small></td>      <td valign="top" width="16%"><small><strong>Item</strong></small></td>      <td valign="top" width="32%"><small><strong>Technical Requirements</strong></small></td>      <td valign="top" width="20%"><small><strong>Comments</strong></small></td>      <td valign="top" width="8%"><small><strong>Yes</strong></small></td>      <td valign="top" width="8%"><small><strong>No</strong></small></td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.1.3(7)<br>        4.13.1 </small></td>      <td valign="top" width="16%"><small>Doors - Accessible Entrances: </small></td>      <td valign="top" width="32%"><small>Is there at least one accessible door         complying with 4.13 (see below) at each accessible entrance to the building         or facility?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%"><small>Accessible Spaces: </small></td>      <td valign="top" width="32%"><small>Is there at least one accessible door         complying with 4.13 (see below) at each accessible space in the facility?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%"><small>Accessible Routes: </small></td>      <td valign="top" width="32%"><small>Does each door that is an element of         an accessible route comply with 4.13 (See below)?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%"><small>Egress Door and Areas of Rescue Assistance:         </small></td>      <td valign="top" width="32%"><small>Does each door that is an element of         an accessible means of egress or that connects to an area of rescue assistance         comply with 4.13 (See below)?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.13.2</small></td>      <td valign="top" width="16%"><small><strong>Revolving Doors and Turnstiles</strong>:         </small></td>      <td valign="top" width="32%"><small>If a revolving door or turnstile is         used on an accessible route, is an accessible door or gate provided adjacent         to the turnstile or revolving door to facilitate the same use pattern?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.13.3</small></td>      <td valign="top" width="16%"><small><strong>Gates</strong>: </small></td>      <td valign="top" width="32%"><small>Do gates, including ticket gates, meet         the applicable specifications of 4.13 (See below)?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.13.5 </small></td>      <td valign="top" width="16%"><small><strong>Clear Opening: </strong></small></td>      <td valign="top" width="32%"><small>When a door is open 90 degrees, is there         a clear opening width at least 32 inches measured between the face of         the door and the door stop on the latch side?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%"><small>Closets: </small></td>      <td valign="top" width="32%"><small>If the door does not require full-user         passage, such as that to a shallow closet, is the clear opening width         at least 20 inches?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.13.4 </small></td>      <td valign="top" width="16%"><small>Double Leaf Doors: </small></td>      <td valign="top" width="32%"><small>If the doorway has two independently         operated door leaves, does at least one active leaf provide at least a         32 inch clear opening width?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.13.6 </small></td>      <td valign="top" width="16%"><small>Maneuvering Space: </small></td>      <td valign="top" width="32%">&nbsp;        <p><small>If the door is not automatic or power assisted, does it have           maneuvering space relative to the direction of approach as shown in           Figure 25?</small></p>        <p><small><strong>EXCEPTION: Entry doors to acute care hospital bedrooms           are exempt from the requirement for the 18 inch space at the latch side           of the door if the door is at least 44 inches wide. </strong></small></p>      </td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="32%"><small>Is the floor level and clear within         the required maneuvering space?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.13.7 </small></td>      <td valign="top" width="16%"><small>Vestibules - Doors in Series: </small></td>      <td valign="top" width="32%"><small>If there are two doors in a series,         is the clear space between doors in a vestibule at least 48 inches plus         the width of any door swinging into the space? (See Figure 26) Do doors         in a series swing in the same direction? OR Do they swing away from the         space between the doors?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.13.8 </small></td>      <td valign="top" width="16%"><small>Thresholds: </small></td>      <td valign="top" width="32%"><small>Is the threshold at doorways no higher         than 3/4 inch in height for exterior sliding doors? Is the threshold no         higher than 1/2 inch for other doors? If there is a raised threshold,         is it beveled at 1:2 or less?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.13.9 </small></td>      <td valign="top" width="16%"><small>Hardware: </small></td>      <td valign="top" width="32%"><small>Are all handles, locks, and latches         or other operative devices operable with one hand? </small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="32%"><small>Are they operable without tight grasping,         pinching, or twisting of the wrist? (U-shaped handles, levers, and push         type mechanisms are acceptable designs.) </small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="32%"><small>If there are sliding doors, is the operating         hardware exposed and usable from both sides when the doors are fully open?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="32%"><small>Is the force required to operate the         controls no greater than 5 lbf? (This does not apply to the force required         to retract latch bolts or to disengage other devices that only hold the         door in a closed position.) </small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="32%"><small>Is the operating hardware mounted no         higher than 48 inches above the floor?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.13.10 </small></td>      <td valign="top" width="16%"><small>Door Closers: </small></td>      <td valign="top" width="32%"><small>If the door has a closer, is the closer         adjusted so that from an open position of 70 degrees, the door will take         at least 3 seconds to move to a point 3 inches from the latch (measured         to the leading edge of the door)?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.13.11 </small></td>      <td valign="top" width="16%"><small>Opening Force - Fire Doors:</small></td>      <td valign="top" width="32%"><small>Do fire doors have the minimum opening         force allowable by the appropriate local authority?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%"><small>Interior Doors: </small></td>      <td valign="top" width="32%"><small>Do interior hinged doors, and sliding         or folding doors, have an opening force of 5 lbf or less?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.13.12 </small></td>      <td valign="top" width="16%"><small>Automatic Doors: </small></td>      <td valign="top" width="32%"><small>If an automatic door is used, does it         comply with ANSI/BHMA A156.10-1985?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%"><small>Low Powered Doors: </small></td>      <td valign="top" width="32%"><small>If there is a slow-opening, low-powered         automatic door, does it comply with ANSI A156.19-1984 and does it take         at least 3 seconds to open to back check? </small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="32%"><small>Do such doors require no more than 15         lbf to stop door movement?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%"><small>Power Assisted Doors:</small></td>      <td valign="top" width="32%"><small>If a power assisted door is used, does         it have an opening force of 5 lbf or less and does its closing conform         to the requirements in ANSI A156.19-1984?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    </tbody>  </table></div><p align="center"><br>  <img src="/SurveySheets/figures/fig25a.gif" width="425" height="539"></p><p align="center"><img height="250" width="370" alt="Maneuvering Clearances at Doors " src="/SurveySheets/figures/fig25.gif"></p><p align="center"><b>Figure 25<br>  Maneuvering Clearances at Doors </b></p><p><b>NOTE: All doors in alcoves shall comply with the clearances for front approaches.   </b></p><p><b>Diagram (a) Front Approaches -- Swinging Doors. Front approaches to pull   side of swinging doors shall have maneuvering space that extends 18 in (455   mm) minimum beyond the latch side of the door and 60 in (1525 mm) minimum perpendicular   to the doorway. </b></p><p><b>Front approaches to push side of swinging doors, equipped with both closer   and latch, shall have maneuvering space that extends 12 in (305 mm) minimum   beyond the latch side of the door and 48 in (1220 mm) minimum perpendicular   to the doorway. </b></p><p><b>Front approaches to push side of swinging doors, not equipped with latch   and closer, shall have maneuvering space that is the same width as door opening   and extends 48 in (1220 mm) minimum perpendicular to the doorway. </b></p><p><b>Diagram (b) Hinge Side Approaches. Hinge-side approaches to pull side of   swinging doors shall have maneuvering space that extends 36 in (915 mm) minimum   beyond the latch side of the door if 60 in (1525 mm) minimum is provided perpendicular   to the doorway or maneuvering space that extends 42 in (1065 mm) minimum beyond   the latch side of the door shall be provided if 54 in (1370 mm) minimum is provided   perpendicular to the doorway. </b></p><p><b>Hinge-side approaches to push side of swinging doors, not equipped with   both latch and closer, shall have a maneuvering space of 54 in (1370 mm) minimum,   parallel to the doorway and 42 in (1065 mm) minimum, perpendicular to the doorway.   </b></p><p><b>Hinge side approaches to push side of swinging doors, equipped with both   latch and closer, shall have maneuvering space of 54 in (1370 mm) minimum, parallel   to the doorway, 48 in (1220 mm) minimum perpendicular to the doorway. </b></p><p><b>Diagram (c) Latch Side Approaches -- Swinging Doors. Latch-side approaches   to pull side of swinging doors, with closers, shall have maneuvering space that   extends 24 in (610 mm) minimum beyond the latch side of the door and 54 in (1370   mm) minimum perpendicular to the doorway. </b></p><p><b>Latch-side approaches to pull side of swinging doors, not equipped with   closers, shall have maneuvering space that extends 24 in (610 mm) minimum beyond   the latch side of the door and 48 in (1220 mm) minimum perpendicular to the   doorway. </b></p><p><b>Latch-side approaches to push side of swinging doors, with closers, shall   have maneuvering space that extends 24 in (610 mm) minimum parallel to the doorway   beyond the latch side of the door and 48 in (1220 mm) minimum perpendicular   to the doorway. </b></p><p><b>Latch-side approaches to push side of swinging doors, not equipped with   closers, shall have maneuvering space that extends 24 in (610 mm) minimum parallel   to the doorway beyond the latch side of the door and 42 in (1065 mm) minimum   perpendicular to the doorway. </b></p><p><b>Diagram (d) Front Approach -- Sliding Doors and Folding Doors. Front approaches   to sliding doors and folding doors shall have maneuvering space that is the   same width as the door opening and shall extend 48 in (1220 mm) minimum perpendicular   to the doorway. </b></p><p><b>Diagram (e). Slide-side approaches to sliding doors and folding doors shall   have a maneuvering space of 54 in (1370 mm) minimum, parallel to the doorway,   and 42 in (1065 mm) minimum, perpendicular to the doorway. </b></p><p><b>Diagram (f) Latch Side Approach -- Sliding Doors and Folding Doors. Latch-side   approaches to sliding doors and folding doors shall have a maneuvering space   that extends 24 in (610 mm) minimum beyond the latch side of the door and extends   42 in (1065 mm) minimum perpendicular to the doorway. </b></p><p><b>Depending on the direction of approach, diagrams (a) through (f) illustrate   minimum maneuvering space depths and latch side clearances for both push and   pull sides of swinging, sliding and folding doors. (4.13.6). </b></p><p align="center">***</p><p align="center"><img height="142" width="392" alt="Two Hindged Doors in Series" src="/SurveySheets/figures/fig26.gif">   <br>  <b>Figure 26<br>  Two Hindged Doors in Series </b></p><p align="center"><b>&nbsp;</b></p><p align="center"><a href="/SurveySheets/SurveyForm.html"><big>Back to Accessibility   Guidelines Checklist for Building and Facilities</big></a></p></body></html>