<html><head><title>SURVEY FORM 5: DRINKING FOUNTAINS</title></head><body><table style="border: medium solid ;" width="100%" cellspacing="1" cellpadding="4" border="1">  <tbody>   <tr>     <td width="100%"><strong>SURVEY FORM 5: DRINKING FOUNTAINS</strong></td>    <td width="100%">       <div align="right"><strong>ADA Build it Right, Inc.</strong></div>    </td>  </tr>  </tbody> </table><font size="2"><br></font> <table style="border: thin inset ;" width="100%" cellspacing="1" border="1">  <tbody>  <tr>     <td align="left" valign="top" width="69%"><strong><font size="3">Facility       Name:</font></strong>      <p>&nbsp;</p>    </td>    <td align="left" valign="top" width="64%">&nbsp;</td>  </tr>  <tr>     <td colspan="2" align="left" valign="top" width="100%"><strong>Fountain Location:<br>      </strong></td>  </tr>  </tbody></table><p>&nbsp;</p><div align="left">   <table style="border: thin inset ;" width="100%" cellspacing="1" border="1">    <tbody>    <tr>       <td valign="top" width="16%"><small><strong>Section</strong></small></td>      <td valign="top" width="16%"><small><strong>Item</strong></small></td>      <td valign="top" width="32%"><small><strong>Technical Requirements</strong></small></td>      <td valign="top" width="20%"><small><strong>Comments</strong></small></td>      <td valign="top" width="8%"><small><strong>Yes</strong></small></td>      <td valign="top" width="8%"><small><strong>No</strong></small></td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.1.3(10)(a)<br>        4.15.1 </small></td>      <td valign="top" width="16%"><small>Water Fountains: </small></td>      <td valign="top" width="32%"><small>Where there is only one drinking fountain         on a floor, is there one accessible to wheelchair users in accordance         with 4.15 (see below) and one accessible to persons who have difficulty         bending or stooping (e.g., drinking fountains mounted at standard height         or a water cooler)?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.1.3(10)(b)<br>        4.15.1 </small></td>      <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="32%"><small>Where there is more than one drinking         fountain on a floor, do 50% comply with 4.15 (See below)?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.1.3(10)</small></td>      <td valign="top" width="16%"><small>Accessible Route: </small></td>      <td valign="top" width="32%"><small>Is the accessible drinking fountain         on an accessible route?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.15.5(2) </small></td>      <td valign="top" width="16%"><small>Clearance - Fountains Without Knee Space:         </small></td>      <td valign="top" width="32%"><small>If the unit is free-standing or built-in         and does not have a clear space underneath it, does it have a clear floor         space alongside it at least 30 by 48 inches which allows a wheelchair         user to make a parallel approach? (See Figures 27(c) and (d))</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.15.5(1)</small></td>      <td valign="top" width="16%"><small>Fountains With Knee Space:</small></td>      <td valign="top" width="32%"><small>If the unit is wall- or post-mounted,         is there a clear knee space between the bottom of the apron and the floor         which is at least 27 inches high, 30 inches wide, and 17 to 19 inches         deep? (See Figures 27(a) and (b)) </small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="32%"><small>Does such a unit also have a clear floor         space at least 30 by 48 inches perpendicular to the unit allowing a forward         approach?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.4.1 </small></td>      <td valign="top" width="16%"><small>Protruding Objects: </small></td>      <td valign="top" width="32%"><small>If a wall mounted drinking fountain         has a leading edge between 27 and 80 inches from the floor, does it project         less than 4 inches into the pathway? (Wall mounted fountains with leading         edges at or below 27 inches may project any amount so long as the required         clear width of an accessible route is not reduced).</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.15.2 </small></td>      <td valign="top" width="16%"><small>Spout - Height:</small></td>      <td valign="top" width="32%"><small>Is the spout outlet no higher than 36         inches from the floor? </small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.15.3</small></td>      <td valign="top" width="16%"><small>Location</small></td>      <td valign="top" width="32%"><small>Is the spout at the front of the unit,         with a water flow trajectory parallel or nearly parallel to the front         edge? </small>        <p>&nbsp;</p>      </td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%"><small>Water Flow</small></td>      <td valign="top" width="32%"><small>If the fountain has a round or oval         bowl, is the water flow within 3 inches of the front edge of the fountain?         </small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="32%"><small>Is the water flow at least 4 inches         high to allow the insertion of a cup under the flow?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.15.4 </small></td>      <td valign="top" width="16%"><small>Controls - Location:</small></td>      <td valign="top" width="32%"><small>Are the controls located on the front         or the side near the front edge?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%"><small>4.15.4<br>        4.27.4 </small></td>      <td valign="top" width="16%"><small>Operation: </small></td>      <td valign="top" width="32%"><small>Are the controls operable with one hand?&nbsp;         </small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="32%"><small>Are the controls operable without tight         grasping, pinching, or twisting of the wrist?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    <tr>       <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="16%">&nbsp;</td>      <td valign="top" width="32%"><small>Is the force to operate the controls         no greater than 5 lbf?</small></td>      <td valign="top" width="20%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>      <td valign="top" width="8%">&nbsp;</td>    </tr>    </tbody>  </table></div><p align="center"><img height="250" width="235" alt="Drinking Fountains and WaterCoolers - Spout Height and Knee Clearance" src="/SurveySheets/figures/fig27a.gif"> </p><p align="center"><b>Figure 27a<br>  Drinking Fountains and Water Coolers - Spout Height and Knee Clearance </b></p><p align="center"><b>In addition to clearances discussed in the text, the following   knee clearance is required underneath the fountain: 8 inches (205 mm) minimum   measured from the front edge underneath the fountain back towards the wall,   and a 9 inch (230 mm) minimum high toe space, measured a maximum 6 inches (150   mm) from the wall. (4.15.2, 4.15.5)</b></p><p align="center"><b>***<br>  <img height="250" width="218" alt="Drinking Fountains and Water Coolers - Clear Floor Space" src="/SurveySheets/figures/fig27b.gif"><br>  Figure 27b</b></p><p align="center"><b>Drinking Fountains and Water Coolers - Clear Floor Space</b></p><p align="center"><b>***<br>  </b></p><p align="center"><b>&nbsp;<img height="250" width="231" alt="Drinking Fountains and Water Coolers - Free-Standing Fountain or Cooler" src="/SurveySheets/figures/fig27c.gif"></b></p><p align="center"><b>Figure 27c</b></p><p align="center"><b>Drinking Fountains and Water Coolers - Free-Standing Fountain   or Cooler</b></p><p align="center"><b>***</b></p><p align="center"><b>&nbsp;<img height="200" width="241" alt="Drinking Fountains and Water Coolers - Built-In Fountain or Cooler" src="/SurveySheets/figures/fig27d.gif">   </b></p><p align="center"><b><br>  Figure 27d<br>  Drinking Fountains and Water Coolers - Built-In Fountain or Cooler </b></p><p align="center"><a href="/SurveySheets/SurveyForm.html"><big>Back to Accessibility   Guidelines Checklist for Building and Facilities</big></a></p></body></html>
